Ultra Subminiature Basic SwitchSubminiature Size Ideal for PCB

Mounting (12.8 6.5 5.8 (W H D))

Incorporating a snapping mechanism made withtwo highly precise split springs that ensures a longservice life.

Insertion molded terminals and a two-stage bottomwith different levels prevent flux penetration.Self-clinching PCB, right-angle, and solder termi-nals are available.

Meets a wide range of applications, including homeappliances, audio equipment, office machines, andcommunications equipment.D2FRCOrdering Information Model Number LegendD2F-jjjj

1

2

3

4

1.

Ratings

None:General load01:0.1 A at 30 VDC

Operating Force max.None:1.47 N {150 gf}F:0.74 N {75 gf}

Note:These values are for the pin plunger model.Actuator

None:Pin plungerL:Hinge leverL2:Hinge roller leverL3:Simulated roller lever

4.

2.

Terminals

None:PCB terminal/straight terminal-T:Self-clinching PCB terminal-A:Right-angle PCB terminal-D3:Solder terminal-D:Compact solder terminal

3.

D2F List of ModelsActuatorOperating force (OF)(see note)Pin plungerpgPCB terminalsSelf-clinchingterminalsRight-angleterminalsSolder terminalsCompact solderterminalsHinge levergPCB terminalsSelf-clinchingterminalsRight-angleterminalsSolder terminalsCompact solderterminalsSimulatedroller leverlllPCB terminalsSelf-clinchingterminalsRight-angleterminalsSolder terminalsCompact solderterminalsHinge rollerglleverPCB terminalsSelf-clinchingterminalsRight-angleterminalsSolder terminalsCompact solderterminalsNote:

Micro voltage/current load0.1 ALow operatingforce 0.74 N {75 gf}D2F-01FD2F-01F-TD2F-01F-AD2F-01F-D3D2F-01F-DD2F-01FLD2F-01FL-TD2F-01FL-AD2F-01FL-D3D2F-01FL-DD2F-01FL3D2F-01FL3-TD2F-01FL3-AD2F-01FL3-D3D2F-01FL3-DD2F-01FL2D2F-01FL2-TD2F-01FL2-AD2F-01FL2-D3D2F-01FL2-DGeneral-purpose1.47 N {150 gf}D2F-01D2F-01-TD2F-01-AD2F-01-D3D2F-01-DD2F-01LD2F-01L-TD2F-01L-AD2F-01L-D3D2F-01L-DD2F-01L3D2F-01L3-TD2F-01L3-AD2F-01L3-D3D2F-01L3-DD2F-01L2D2F-01L2-TD2F-01L2-AD2F-01L2-D3D2F-01L2-D1 ALow operatingforce 0.74 N {75 gf}D2F-FD2F-F-TD2F-F-AD2F-F-D3D2F-F-DD2F-FLD2F-FL-TD2F-FL-AD2F-FL-D3D2F-FL-DD2F-FL3D2F-FL3-TD2F-FL3-AD2F-FL3-D3D2F-FL3-DD2F-FL2D2F-FL2-TD2F-FL2-AD2F-FL2-D3D2F-FL2-DStandard3 AD2FGeneral-purpose1.47 N {150 gf}D2FD2F-TD2F-AD2F-D3D2F-DD2F-LD2F-L-TD2F-L-AD2F-L-D3D2F-L-DD2F-L3D2F-L3-TD2F-L3-AD2F-L3-D3D2F-L3-DD2F-L2D2F-L2-TD2F-L2-AD2F-L2-D3D2F-L2-DThe OF values shown in the table are for the pin plunger models.

SpecificationsRatings

Item

OF max.

D2F models

1.47 N {150 gf}(General-purpose)3 A2 A

0.74 N {75 gf}(Low operating)1 A0.5 A

D2F-01 models

1.47 N {150 gf}(General-purpose)---0.1 A

0.74 N {75 gf} (Low operating)

Resistive load

Rated voltageNote:

125 VAC30 VDC

1.Consult your OMRON representative before using the Switch with inductive or motor loads.2.The ratings values apply under the following test conditions: Ambient temperature: 20±2°CAmbient humidity: 65±5%

Operating frequency: 30 operations/min

D2FCharacteristics

Operating speedOperating frequencyInsulation resistanceContact resistance (initial value)Dielectric strength

1 to 500 mm/s (at pin plunger models)Mechanical:200 operations/minElectrical:30 operations/min100 MΩ min. (at 500 VDC)D2F models:D2F-F models:D2F-01 models:

30 mΩ max.50 mΩ max. 100 mΩ max.

D2F600 VAC, 50/60 Hz for 1 min between terminals of the same polarity

1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground (see note 1), andbetween each terminal and non-current-carrying metal partMalfunction: 10 to 55 Hz, 1.5-mm double amplitudeDestruction:1,000 m/s2 {approx. 100G} max.Malfunction:300 m/s2 {approx. 30G} max.

Mechanical:1,000,000 operations min. (Refer to Engineering Data.)Electrical:30,000 operations min. (Refer to Engineering Data.)IP00Class I175

Operating: –25°C to 65°C (at ambient humidity of 60% max.) (with no icing)Operating: 85% max. (for 5°C to 35°C)Approx. 0.5 g (pin plunger models)

Vibration resistance (see note 2)Shock resistance (see note 2)Life expectancyDegree of protectionDegree of protection againstelectric shock

Proof tracking index (PTI)Ambient temperatureAmbient humidityWeightNote:

1.The dielectric strength shown in the table indicates a value for models with a Separator.

2.For the pin plunger models, the values are at the free position and total travel position. For the lever models, they are at the totaltravel position.

Approved StandardsUL10 (File No. 41515)

CSA C22.2 No. 55 (LR212)Ratedvoltage125 VAC30 VDC

D2F (general-purpose)3 A2 A

D2F (lowoperatingforce)1 A0.5 A

---0.1 A

D2F-01

Contact FormSPDT

Contact SpecificationsItem

Contact

SpecificationMaterialGap

(standardvalue)

Minimum applicable load

D2F modelsCrossbarSilver alloy0.25 mm

Gold alloyD2F-01 models

COMNONC100 mA at 5 VDC

1 mA at 5 VDC

D2FD2FEngineering DataMechanical Life Expectancy (D2F, D2F-01)

10,0007,000

Ambient temperature: 20°±2°CAmbient humidity:65±5% max.Without load

Operating frequency:60 operations/min

Electrical Life Expectancy (D2F)

300

Ambient temperature: 20°±2°CAmbient humidity:65±5% max.Without load

Operating frequency:30 operations/min

Number of operations (x10 3 )5,0003,000

Number of operations (x10 3 )100

125 VAC

50302010

30 VDC

1,000700500300100

0

OT (mm)

The values are for the pin plunger model.

Switching current (A)

For details about the D2F-01, contact yourOMRON sales representative.

DimensionsNote:All units are in millimeters unless otherwise indicated. TerminalsPCB Terminals (Standard)

Self-clinching PCB Terminals

1.53.5

3.15

6.5±0.15.085.0812.8±0.15

0.9

0.45.8±0.15

3.15

6.5±0.1

1.53.40.9

0.4±0.051.25±0.15

5.8±0.15

1.6±0.151.5

5.085.0812.8±0.15

Right-angle PCB Terminals

PCB Mounting Dimensions (Reference)

2.1.5

2.6±0.2

3.15

6.5±0.15.085.0812.8±0.15

0.9

5.8±0.15

0.4

3.1±0.2

5.8± 0.152.5.08± 0.112.8± 0.15Three,1.2 dia. holesSolder Terminals

Compact Solder Terminals

1.5

20.5

3.15

6.5±0.1

5.085.08

12.8±0.15

3.51.22.2

0.45.8±0.15

Three, 0.8-dia. holes

3.15

6.5±0.15.085.0812.8±0.15

1.52.41.6

0.45.8±0.15

D2F Mounting HolesTwo , 2-dia. mounting holesD2F6.5± 0.15 Dimensions and Operating CharacteristicsNote:

1.All units are in millimeters unless otherwise indicated.

2.Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

3.The following illustrations and drawings are for D2F models with PCB terminals. Self-clinching, solder, and right-angle terminals areomitted from the following drawings. Refer to page 180 for these terminals. When ordering, replace j with the code for the terminalthat you need.4.The operating characteristics are for operation in the A direction ().Pin Plunger

D2FjD2F-01jD2F-FjD2F-01Fj

Hinge Lever

D2F-LjD2F-01LjD2F-FLjD2F-01FLj

Simulate Roller Lever

D2F-L3j

D2F-01L3jD2F-FL3jD2F-01FL3j

1.2

12.7PT5.7

2.2+0.122.9

0dia.A5.2

2+0.120dia. holes5

OP2+0.1201.53.5

3.15

6.5±0.10.9

0.45.085.08

12.8±0.15

5.8±0.15

12.8

(10.8)

3

t = 0.3 (see note)

AFPOP

Note:Stainless-steel lever

12.7(7.5)A102.1

t = 0.3 (see note)

3

1.3R

OP

FP

Note:Stainless-steel lever

Model

D2FjD2F-Fj

D2F-01jD2F-01FjOF max.1.47 N {150 gf}{g}0.74 N {75 gf}{g}RF min.0.20 N {20 gf}0.05 N {5 gf}

PT max.0.5 mmOT min.0.25 mmMD max.0.12 mmOP

5.5±0.3 mm

ModelD2F-LjD2F-FLj

D2F-01LjD2F-01FLjOF max.0.78 N {80 gf}{g}0.25 N {25 gf}{g}RF min.

0.05 N {5 gf}0.02 N {2 gf}

OT min.0.55 mmMD max.0.5 mmFP max.10 mmOP

6.8±1.5 mm

Model

D2F-L3jD2F-FL3j

D2F-01L3jD2F-01FL3jOF max.0.78 N {80 gf}{g}0.39 N {40 gf}{g}RF min.0.05 N {5 gf}0.02 N {2 gf}

OT min.0.5 mmMD max.0.45 mmFP max.13 mmOP

8.5±1.2 mm

D2FHinge Roller Lever

D2F-L2jD2F-01L2jD2F-FL2jD2F-01FL2j

12.8

(10)

4

A4.8 dia. × 2.8 (Resin roller)

(4.6)

t = 0.3(seenote)

D2FModelOF max.RF min.OT min.

4OPFP

D2F-L2jD2F-01L2j0.78 N {80 gf}{g}0.05 N {5 gf}0.55 mm0.5 mm16.5 mm13±2 mm

D2F-FL2j

D2F-01FL2j0.39 N {40 gf}{g}0.02 N {2 gf}

MD max.FP max.OP

Note:Stainless-steel lever

PrecautionsRefer to pages 26 to 33 for common precautions.Using Micro LoadsUsing a model for ordinary loads to open or close the contact of a

micro load circuit may result in faulty contact. Use models that oper-ate in the following range. However, even when using micro loadmodels within the operating range shown below, if inrush current oc-curs when the contact is opened or closed, it may increase contactwear and so decrease life expectancy. Therefore, insert a contactprotection circuit where necessary.

The minimum applicable load is the N-level reference value. Thisvalue indicates the malfunction reference level for the reliability lev-el of 60% (λ 60). The equation, λ 60 = 0.5 10–6/operations indi-cates that the estimated malfunction rate is less than 1/2,000,000operations with a reliability level of 60%.

Voltage (V) CautionsTerminal Connection

When solderingthe lead wire to the terminal, first insert the lead wireconductor through the terminal hole and then conduct soldering.Make sure that the capacity of the soldering iron is 30 W maximum(temperature of soldering iron: 350°C max.). Do not take more than3 s to solder the switch terminal.

If soldering is not carried out under the proper conditions there is adanger of over-heating and subsequent heat damage.

Applying a soldering iron for more than 3 s or using one that is ratedat more than 30 W may deteriorate the Switch characteristics.When soldering the lead wire to the PCB terminal, pay careful atten-tion so that the flux and solder liquid level does not exceed the PCBlevel.

Correct UseMounting

Turn OFF the power supply before mounting or removing theSwitch,wiring, or performing maintenance or inspection. Failure todo so may result in electric shock or burning.

Use M2 mounting screws with plane washers or spring washers tosecurelymount the Switch. Tighten the screws to a torque of 0.08 to0.1 N•m {0.8 to 1 kgf•cm}.

Mount the Switch onto a flat surface. Mounting on an uneven sur-facemay cause deformation of the Switch, resulting in faulty opera-tion or breakage in the housing.

Operating rangefor micro loadmodels D2F-01

Operatingrange forgeneral-loadmodelsD2F

Inoperablerange

Operating Stroke Setting

Take particular care in setting the operating stroke for the pin plung-er models. Make sure that the operating stroke is 70% to 100% ofthe rated OT distance. Do not operate the actuator exceeding theOT distance, otherwise the life expectancy of the Switch may beshortened.

Current (mA)

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. B036-E1-07B

因篇幅问题不能全部显示,请点此查看更多更全内容

Copyright © 2019- igat.cn 版权所有 赣ICP备2024042791号-1

违法及侵权请联系:TEL:199 1889 7713 E-MAIL:2724546146@qq.com

本站由北京市万商天勤律师事务所王兴未律师提供法律服务