Page 1 of 12 Report No. 30880025.007

TEST REPORT IEC 60950-1: 2005 (2nd Edition) Information technology equipment – Safety – Part 1: General requirements Report Reference No...........................: 30880025.007 Date of issue..........................................: March 20, 2009 Total number of pages............................ 12 CB Testing Laboratory........................: Address..................................................: Applicant’s name.................................: Address..................................................: Manufacturer’s name...........................: Address..................................................: Factory’s name.....................................: Address..................................................: Test specification: TUV Rheinland of North America, Inc. 1279 Quarry Lane, Ste. A, Pleasanton, CA 94566 Myricom, Inc. 325 N. Santa Anita Ave., Arcadia CA 91006 Myricom, Inc. Myricom, Inc., 325 N. Santa Anita Ave., Arcadia CA 91006 Myricom, Inc. Myricom, Inc., 325 N. Santa Anita Ave., Arcadia CA 91006 Standard................................................: IEC 60950-1:2005 (2nd Edition) ( Information technology equipment –Safety –Part1: General requirements) Test procedure.......................................: CB Non-standard test method…………..: Test Report Form No...........................: Test Report Form(s) Originator..............: Master TRF............................................: N/A IECEN60950_1C SGS Fimko Ltd Dated 2007-06 Copyright © 2007 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. If this Test Report Form is used by non-CCA members, the CIG logo and the reference to the CCA Procedure shall be removed. This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory and appended to a CCA Test Certificate issued by an NCB in accordance with CCA Test item description...........................: Trade Mark.............................................: LAN Switch Manufacturer...........................................: Model/Type reference.............................: Myricom, Inc., 325 N. Santa Anita Ave., Arcadia CA 91006 10G-21U-CLOS-ENCL, 10G-21U-EDGE-ENCL, 10G-12U-CLOS-ENCL, TRF No. IECEN60950_1C R1100950.005, Revision 1

Ratings....................................................:

Page 2 of 12 Report No. 30880025.007

10G-12U-SPINE-ENCL, 10G-7U-CLOS-ENCL, 10G-7U-SPINE-ENCL Input: 100-240V, 50/60 Hz, 10A-5A (rating per input, up to 4 inputs)

TRF No. IECEN60950_1C R1100950.005, Revision 1

General remarks:

Page 3 of 12 Report No. 30880025.007

The test results presented in this report relate only to the object tested.

This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.

\"(See Enclosure #)\" refers to additional information appended to the report. \"(See appended table)\" refers to a table appended to the report.

Note: This TRF includes EN Group Differences together with National Differences and Special

National Conditions, if any. All Differences are located in the Appendix to the main body of this TRF. Throughout this report a comma (point) is used as the decimal separator.

General product information:

This test report is Amendment 2 to the original CB-report with document number 30880025.001 and the first amendment CB report 30880025.004 and covers the addition of new line cards 10G-THRU-16Q, 10G-THRU-8M8ER, 10G-THRU-16WQP, 10G-SW32LC-16QP, 10G-S SW32LC-16ES, 10G-SW32LC-16EM. Each line card uses less power than line cards that have already been evaluated for the original report and subsequent amendment so no testing was performed as part of this investigation and the new line cards have been evaluated on a constructional basis only. Critical components within the line cards being added include Certified Class 1 lasers only.

The product covered in this test report are LAN Switches with the model numbers: 10G-21U-CLOS-ENCL, 10G-21U-EDGE-ENCL, 10G-12U-CLOS-ENCL, 10G-12U-SPINE-ENCL, 10G-7U-CLOS-ENCL and 10G-7U-SPINE-ENCL. The LAN Switch product comes with six different configuration codes: 10G-21U-CLOS-ENCL has the CLOS backplane boards, which accept eight 10G-2SW32LC line cards in the middle, one 10G-MONITOR-B in the top, and nearly any combination of the other line cards in the other slots. The 10G-21U-EDGE-ENCL has one 10G-MONITOR-B in the top, and the other slots accepts nearly any combination of the other line cards, excluding the 10G-2SW32LC line card (For details of line cards, see critical components list table 1.5.1). The 12U and 7U configurations are similar in functional configuration with the differences being the 12U is a smaller chassis intended for use with 2-4 power supplies and the 7U is a still smaller chassis intended for use with 1-2 power supplies. The 12U configuration was tested per this

investigation and it was determined via the test results and inspection that the data taken for the 21U is representative of the 12U and 7U and as such the previously-measured 21 test results are applied to this report amendment.

The enclosures contain a metal chassis, up four approved power supplies (different for each model), approved DC fans, a backplane, AC-Inlet/Filter and interface cards, which are all interchangeable. Model No. 10G-21U-CLOS-ENCL is a ‘21U high, 41-slot enclosure for switch networks up to 512 ports’ located on the rear panel of the unit. These ports are

connected to copper and fiber cables and there is no power available on these ports. All signals are AC coupled through 470pF capacitors

During the testing the maximum power was generated by using resistive loads. Due to the expenses of each individual card, a low-cost test configuration with these resistive loads cards generating 200W of power was used for the temperature rise measurement and abnormal fault conditions.

It should be noted that for the final configuration of the LAN Switches each individual card has two redundant temperature sensors which control the power to a card (thermal cut-out / power off at 60˚C). Also, the four DC fans at the back-side of the products are speed-adjustable depending on the temperature inside the LAN Switch enclosure. Individual temperature sensors are located on each line card and each fan controller PCB

Model 10G-21U-CLOS-ENCL is intended to be fully operational with a minimum of three power supplies only. However, the four power supply configuration is intended for triple-AC systems( where there are three different sources of AC

TRF No. IECEN60950_1C R1100950.005, Revision 1

Page 4 of 12 Report No. 30880025.007

power), and the enclosure will continue to run will continue to run with one AC off and one power supply down. The unit contains; four fans, four power supplies and thirty cards – mixed. There are no connections to a Telecommunication Network (TNV).

CDRH-Report for Optical Transceiver has to be provided by customer for US Approval.

During the testing the maximum power was generated by using resistive loads. Due to the expenses of each individual card a low-cost test configuration with these resistive load cards, generating 200W of power, was used for the temperature rise measurements and abnormal fault conditions.

Conditions of Acceptability: 1.This unit is considered to operate under the conditions of:

– Pollution Degree 2: Not sealed, not subjected to dust, dirt, and condensation – Equipment mobility: Rack mounted / fixed

2. Rated ambient of 40°C at maximum rated load

TRF No. IECEN60950_1C R1100950.005, Revision 1

Testing procedure and testing location: CB/CCA Testing Laboratory: Page 5 of 12 Report No. 30880025.007

Testing location/ address.......................:TUV Rheinland of North America, Inc. Associated CB Laboratory: N/A 1279 Quarry Lane, Ste. A, Pleasanton, CA 94566 Testing location/ address.......................: Tested by (name + signature).....:Stephen Ross Approved by (+ signature)..........:Uwe Meyer Testing procedure: TMP N/A Tested by (name + signature).....: Approved by (+ signature)...........: Testing procedure: WMT N/A Testing location/ address.......................: Tested by (name + signature).....: Witnessed by (+ signature)..........: Approved by (+ signature)..........: Testing location/ address.......................: Testing procedure: SMT N/A Tested by (name + signature).....: Approved by (+ signature)...........: Supervised by (+ signature)........: N/A Testing location/ address................: Testing procedure: RMT Tested by (name + signature).....: Approved by (+ signature)...........: Supervised by (+ signature)........: Testing location/ address.......................: TRF No. IECEN60950_1C R1100950.005, Revision 1

Summary of testing:

Tests performed (name of test and test clause):

= no testing performed for this amendment =

Page 6 of 12 Report No. 30880025.007

Testing location:

TUV Rheinland of North America, Inc.

1279 Quarry Lane, Ste. A, Pleasanton, CA 94566

Summary of compliance with National Differences: Comments:

Summary of compliance with National Differences (for explanation of codes see below): AT, CA (temporary differences), DE, DK, FI, FR, GB, IT, JP, KR, NL, NO, PL, SE, SI, US (temporary differences).

and Group Differences as listed at the end of this test report Explanation of Codes:

AT=Austria, CA-Canada, DE=Germany, DK=Denmark, FI=Finland, FR=France, GB=United Kingdom, IT=Italy,

JP=Japan, KR=Korea, NL=The Netherlands, NO=Norway, PL=Poland, SE=Sweden, SI=Slovenia, US=United States

The following Attachments are integral part of this test report:

= no attachments for this amendment =

TRF No. IECEN60950_1C R1100950.005, Revision 1

Page 7 of 12 Report No. 30880025.007

Test item particulars..................................................:

Equipment mobility....................................................: [] movable [] hand-held [] transportable

[X] stationary [] for building-in [] direct plug-in Connection to the mains............................................: [] pluggable equipment [] type A [] type B

[] permanent connection

[X] detachable power supply cord [] non-detachable power supply cord [] not directly connected to the mains Operating condition...................................................: [X] continuous

[] rated operating / resting time: Access location .........................................................: [X] operator accessible

[] restricted access location

Over voltage category (OVC) ...................................: [] OVC I [X] OVC II [] OVC III [] OVC IV

[] other: Mains supply tolerance (%) or absolute mains supply values .......................................................................:

Tested for IT power systems ....................................: [X] Yes [] No IT testing, phase-phase voltage (V) .........................: 230V

Class of equipment ...................................................: [X] Class I [] Class II [] Class III

[] Not classified Considered current rating (A) ...................................:

Pollution degree (PD) ...............................................: [] PD 1 [X] PD 2 [] PD 3 IP protection class ....................................................: IPX0 Altitude during operation (m) ....................................: 2000 m Altitude of test laboratory (m) ...................................: 2000 m Mass of equipment (kg) ............................................: 98kg Possible test case verdicts:

- test case does not apply to the test object.................:N/A - test object does meet the requirement.......................:P (Pass) - test object does not meet the requirement.................:F (Fail) Testing..........................................................................: Date of receipt of test item............................................:N/A Date(s) of performance of tests....................................:N/A

[constructional check only, all test data is based on

previously issued reports 30880025.001 and

30880025.004, all changes per this amendment are either non-safety critical or editorial in nature only]

TRF No. IECEN60950_1C R1100950.005, Revision 1

1 GENERAL

1.5 Components 1.5.1 General 1.5.2

Page 8 of 12 Report No. 30880025.007

P P

Complies

Refer to appended table 1.5.1 (list of critical components) All safety critical components are certified. All components are used within their specified ratings, plastic materials, PCBs and wiring materials are UL listed, non-certified components were tested according to this standard.

P P P

Comply with IEC 60950-1 or relevant component standard

Evaluation and testing of components

1.5.1

TABLE: List of critical components

Type/model

Technical data

Standard (Edition

/ year)

P

Mark(s) of conformity1)

CSA, cULus, TUV

Object/part No. Manufacturer/

trademark

IEC/EN/UL60950-1 1.) Power Supply Astec DS850-3 Input: 100-240, UL 1449 (VDR’s) (up to 4 each) 50/60Hz, 10A;

Output: +12V/70A,

2.) DC Fan (up to Delta

8 each)

3.) DC Fan

Controller board

+3.3V/6A

FFB1212EHE-F0012VDC 3.0A –

5.38 mmin

3/

IEC/EN/UL 60950-1

VDE, CE, UL,

CSA

Myricom 05-2896 Minimum UL94 UL flammability rating: V-0,

TRF No. IECEN60950_1C R1100950.005, Revision 1

4.) Internal wiring Various

Various

Page 9 of 12 Report No. 30880025.007

Rated 600V, 105˚C,

flammability rating minimum VW-1 4 wire gage type 10070 from output power distribution board to the power back plane bus bars (2 cables;3 feet long) +/-12V. Wire gages for line/neutral/safety ground: type

“1015” wire , 18ga for +12/- Back plane to

signal/power/fans to backplane 18 ga to 24 ga . Minimum flammability rating:V-0 Minimum flammability rating:V-0 Minimum flammability rating:V-0 Minimum flammability rating:V-0 Minimum flammability rating;V-0 Minimum flammability rating:V-0 Minimum flammability rating:V-0 Minimum flammability rating:V-0 Minimum flammability rating:V-0 Minimum flammability rating:V-0 Minimum flammability rating:V-0 Minimum flammability rating:V-0

-- UL 5.) Cards 6.) Cards 7.) Cards 8.) Cards 9.) Cards 10.) Cards 11.) Cards 12.) Cards 13.) Cards 14.) Cards

Myricom Myricom Myricom Myricom Myricom Myricom Myricom Myricom Myricom Myricom

10G-Monitor –B 10G-SW32LC-16M

10G-THRU-16M 10G-SW32LC-16Q

10G-THRU-16Q 10G-SW32LC-8Q8ER 10G-THRU-8Q8ER 10G-SW32LC-8M8ER 10G-THRU-8M8ER 10G-SW32LC-8M8EM

10G-THRU-8M8EM 10G-SW32LC-16QP

UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL 15.) Cards Myricom UL94 UL 16.) Cards Myricom

UL94 UL

TRF No. IECEN60950_1C R1100950.005, Revision 1

17.) Cards

Myricom

Page 10 of 12 Report No. 30880025.007

10G-THRU-16QP Minimum

flammability rating:V-0 Minimum 10G-SW32LC-flammability 8QP8ER

rating:V-0 10G-SW32LC-16ES 10G-SW32LC-16EM

10G-2SW32LC

Minimum flammability rating:V-0 Minimum flammability rating:V-0

UL94 UL 18.) Cards Myricom UL94 UL 19.) Cards Myricom UL94 UL 20.) Cards Myricom UL94 UL 21.) Cards 22.) Cards 23.) Backplane left

24.) Backplane right

25.) Backplane left

26.) Backplane right

27.) Backplane left

28.) Backplane right

29.) Backplane left

30.) Backplane right

31.) Backplane left

32.) Backplane right

33.) Backplane left

34.) Backplane right

35.)Power Cord (U.K.)

Minimum flammability rating:V-0 Minimum Myricom 10G-FAN v1.0

flammability rating:V-0 Minimum Myricom 10G-21U-CLOS flammability rating:V-0 Minimum Myricom 10G-21U-CLOS flammability rating:V-0 Minimum Myricom 10G-21U-EDGE flammability rating:V-0 Minimum Myricom 10G-21U-EDGE flammability rating:V-0 Minimum Myricom 10G-12U-CLOS flammability rating:V-0 Minimum Myricom 10G-12U-CLOS flammability rating:V-0 Minimum Myricom 10G-12U-EDGE flammability rating:V-0 Minimum Myricom 10G-12U-EDGE flammability rating:V-0 Minimum Myricom 10G-7U-CLOS flammability rating:V-0 Minimum Myricom 10G-7U-CLOS flammability rating:V-0 Minimum Myricom 10G-7U-EDGE flammability rating:V-0 Minimum Myricom 10G-7U-EDGE flammability rating:V-0

Volex 2922 250V, 10A, 13A

fuse, 1mm2 Myricom

UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL UL94 UL -- ASTA, BSI TRF No. IECEN60950_1C

R1100950.005, Revision 1

36.) Power Cord (Germany / Europe)

37.) Power Cord (U.S.)

38.) Power Cord (Japan)

39.) Transceiver ( 10G-SW32LC-16Q/

10G-THRU-16Q/ 10G-SW32LC-8Q8ER/ 10G-THRU-8Q8ER)

40.) Transceiver ( Avago 10G-SW32LC-8Q8ER/ 10G-THRU-8Q8ER/ 10G-SW32LC-16Q/

10G-THRU-16Q)

41.) Transceiver ( Finisar 10G-SW32LC-8M8ER/ 10G-THRU-8M8ER/ 10G-SW32LC-8Q8ER/ 10G-THRU-8Q8ER/ 10G-SW32LC-8QP8ER)

42.) Transceiver ( Finisar 10G-SW32LC-8M8ER/ 10G-THRU-8M8ER/ 10G-SW32LC-8Q8ER/ 10G-THRU-8Q8ER/ 10G-SW32LC-8QP8ER)

FTLX1411D3 FLTX8511D3 HFBR-7934EHZ

Volex or equivalent

17850

or equivalent

Page 11 of 12 Report No. 30880025.007

Rating: 300V, 10A, -- 1.0mm2

VDE, N, FI, S, D, I

Volex 17504 125V, 15A, 14 -- UL, CSA AWG

Feller 5330-440 125V, 15A, -- DENTORI 2.0mm2

ZL60304-MKDA Zarlink Class I M laser IEC/EN 60825-1 TUV, UL

Class I M laser IEC/EN 60825-1 TUV, UL

Class I M laser IEC/EN 60825-1 TUV, UL

Class I M laser IEC/EN 60825-1 TUV, UL

TRF No. IECEN60950_1C

R1100950.005, Revision 1

43.) Transceiver ( Finisar 10G-SW32LC-8M8ER/ 10G-THRU-8M8ER/ 10G-SW32LC-8Q8ER/ 10G-THRU-8Q8ER/ 10G-SW32LC-8QP8ER)

44.) Transceiver ( Zarlink 10G-SW32LC-8QP8ER/ 10G-SW32LC-16QP/ 10G-THRU-16QP)

45.) Transceiver ( Finisar 10G-SW32LC-16ES)

46.) Transceiver ( Finisar 10G-SW32LC-16ES)

47.) Transceiver ( Tyco Electronics 1985554-x

1985861-x

10G-SW32LC-1-198554-0

8QP8ER/ 1-1985861-0 10G-SW32LC-1-1985861-1

16QP/ 10G-THRU-16QP)

3M 48.) Insulation

Tape/ used on the internal chassis adjacent to metal bus bar

49.) Temperature National Sensor Semiconductor 50.) Power Myricom Distribution Board

Type 1206 ZL60505MJDA

Page 12 of 12 Report No. 30880025.007

FTLX1412D3BCL Class I laser

EN 60825-1 EN 60825-2 EN 60950-1

CSA 60950-1-03 CDRH

TUV, CSA, FDA

Class I M laser IEC/EN 60825-1 TUV, UL

FTLX8571D3BCL Class I laser

FTLX1471D3BCL Class I laser

Class I M laser

EN 60825-1 EN 60825-2 EN 60950-1 CDRH

EN 60825-1 EN 60825-2 EN 60950-1 CDRH

EN 60825-1 EN 60825-2 EN 60950-1

CSA 60950-1-03 CDRH

TUV, FDA

TUV, FDA

TUV, CSA, FDA

Rated 155˚C UL510 UL

LM74

3.0V/2.65V to 5.5V, -10˚C to 65˚C Minimum flammability rating:V-0

- - 10G-POWER v1.1.

UL94 UL

END of TEST REPORT

TRF No. IECEN60950_1C R1100950.005, Revision 1