Human Interface Modules (HIM)
22-HIM-A3 — IP20 (NEMA Type 1)22-HIM-C2S — IP66 (NEMA Type 4X/12)0EscALTSelJog|Display Descriptions
➊➋ F Stopped AutoHzAV➌ParametersGroupsLinear ListChanged ParamsF Stopped AutoHzAVViewLangRemove➍➎EscDIAGPARAMDSELMEMSELSel7F At Reference Auto8520963+/-Param # 41AltJog.Output FreqHzDisplay
➊➋
Status Line: Direction | Operating Status | Drive Status | Auto/Manual Mode | Parameters Locked/UnlockedProcess Display screen:•Output Frequency
•User Display Line 1 (HIM Parameter 04)•User Display Line 2 (HIM Parameter 05)Programming screenMenu Navigation Tabs
➌➍➎
Large Format User Display screen:
Key Descriptions
KeysEscDescriptionExit a menu, cancel a change to a parameter value, or acknowledge a fault/alarm.Select a digit, select a bit, or select a menu tab.Scroll through options, increase a value, or toggle a bit.Scroll through options, decrease a value, or toggle a bit.Enter a menu, enter edit mode in a parameter screen, or save a change to a parameter value.Toggle between the Process Display and Large Format Display.Select an available language for text displayed on HIM screens.SelAltplus…ViewSelLangRemoveAllow the HIM to be disconnected without causing a fault condition.+/-Param #Enable direct parameter number entry.Start the drive.Stop the drive or clear a fault. JogChange direction.Jog the drive.0....9+/-Type parameter numbers and values.Increase or decrease the speed Reference to the drive after these keys are enabled by setting drive parameter P038 - [Speed Reference] as follows:•When the HIM is the DSI Master, set parameter P038 to “5” (Comm Port).•When the HIM is the DSI Slave, set parameter P038 to “1” (Internal Freq).To view the HIM’s active device type status (Master or Slave), see HIM Parameter 10 - [M/S Status].Tabs
DIAGPARAMDSELMEMHIM
Menu Navigation Tabs
Description
The Diagnostics tab is used to display faults, the device (drive or peripheral) status, and device version.The Parameters tab is used to edit parameters. Parameters can be displayed in groups, in a linear list, or only those changed from their defaults.
The Device Select tab is used to select the device (drive or peripheral) that the HIM is to access.The Memory Storage tab is used for HIM CopyCat (uploading/downloading configurations to the HIM EEPROM).
The HIM Setup tab is used to access HIM parameters, view the HIM version, and to edit the Reference text when a user-defined Reference is used.
Parameter List
01
[Startup Display]
Selects the display screen shown when the HIM is powered up.
Default:Values
02
0304
05
07
08
09
10
11
06
0 = Main Menu0 = Main Menu1 = Process Disp2 = Large Disp3 = Startup Param
Type:Read/Write
[Startup Param]Default:1Selects a desired drive parameter to be displayed if Parameter 01 - Minimum:1
Maximum:65535[Startup Display] is set to “3” (Startup Param).
Type:Read/Write
Reserved
[User Disp Line 1]Default:3Selects a desired drive parameter to be displayed on User Display Minimum:1
Maximum:65535Line 1 of the Process Display screen.
Type:Read/Write
For example, setting to “3” selects PowerFlex 4-Class drive Parameter 3 - [Output Current] to be displayed.[User Disp Line 2]Default:5Selects a desired drive parameter to be displayed on User Display Minimum:1
Maximum:65535Line 2 of the Process Display screen.
Type:Read/Write
For example, setting to “5” selects PowerFlex 4-Class drive Parameter 5 - [DC Bus Voltage] to be displayed.[Large Disp Param]Default:1
Minimum:0Selects a desired drive parameter to be displayed on the Large
Maximum:65535Format User Display screen.
Type:Read/Write
For example, setting to “1” selects PowerFlex 4-Class drive
Parameter 1 - [Output Freq] to be displayed. Setting to “0” enables the Scaled Reference to be displayed.[LCD Contrast]Default:50%
Minimum:0%Sets the HIM LCD contrast level.
Maximum:100%Type:Read/Write
[Reset HIM]Default:0 = Ready
Values0 = Ready1 (Reset):Resets the HIM.
1 = Reset2 (Set Defaults):Resets HIM parameters to factory settings.
2 = Set Defaults
This parameter returns to a value of “0” (Ready) after the reset
Type:Read/Write
function is complete.[Device Type]Default:0 = Auto
Values0 = AutoSelects the HIM device type. When set to “0” (Auto), the HIM is
1 = Slaveautomatically configured as either a DSI Master or Slave depending
2 = Masteron the presence of other peripheral devices.
Type:Read/Write
[M/S Status]Default:N/A
Values1 = SlaveDisplays the HIM active device type.
2 = Master
Type:Read Only
[HIM Ref Preset]Default:0 = Zero Start
Values0 = Zero Start0 (Zero Start):HIM Reference is always “0.0” at power on.
1 = Host Output
1 (Host Output):HIM will assume the Host’s output feedback
2 = Last HIM Ref
(bumpless transfer) and preset its Reference when
Type:Read/Write
the Reference is configured to be received on the RS-485 port. This can be verified by viewing Diagnostics/Device Status/Remote Freq Ref = 1.
2 (Last HIM Ref):HIM will store the HIM Reference in EEPROM each
time it is changed. HIM Reference is restored at power on.
12
[Ref Scaling]
Enables or disables scaling the Reference to a user-defined value. When Parameter 12 - [Ref Scaling] is set to “1” (Enabled), use HIM Parameters 13…22 to scale the Reference.[Ref Max Value]
Sets the user-defined value to be displayed when the drive is running at 60 Hz.
[Ref Dec Position]
Sets the number of digits to be displayed to the right of the decimal point for the Reference.
[Ref Units Char 1][Ref Units Char 2][Ref Units Char 3][Ref Units Char 4][Ref Units Char 5][Ref Units Char 6][Ref Units Char 7][Ref Units Char 8]
Selects up to 8 characters (from the ISO 8859-1 character set) to use for the Reference units on the Process Display.
Parameters 15…22 can also be configured using the “Edit Ref Text” selection in the HIM Setup tab.[Fault Dspy Type]
Selects the type of display flash to be shown when a drive or peripheral fault is detected.
Default:Values:Type:Default:Minimum:Maximum:Type:Default:Minimum:Maximum:Type:Default:Default:Default:Default:Default:Default:Default:Default:
0 = Disabled0 = Disabled1 = EnabledRead/Write
60010065535Read/Write103
Read/Write72(“H”)122(“z”)
32(blank - no character)32(blank - no character)32(blank - no character)32(blank - no character)32(blank - no character)32(blank - no character)
13
14
1516171819202122
Minimum:32Maximum:255Type:Read/WriteDefault:Values:Type:Default:Values:Type:
0 = Flash Bklite0 = Flash Bklite1 = Flash NoneRead/Write1 = Flash None0 = Flash Bklite1 = Flash NoneRead/Write
24
[Alarm Dspy Type]
Selects the type of display flash to be shown when a drive alarm is detected.
U.S. Allen-Bradley Drives Technical Support
Tel: (1) 262.512.8176, Fax: (1) 262.512.2222, Email: support@drives.ra.rockwell.com, Online: www.ab.com/support/abdrives
www.rockwellautomation.comPower, Control and Information Solutions HeadquartersAmericas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444Europe/Middle East/Africa: Rockwell Automation, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 00Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, , Tel: (852) 2887 4788, Fax: (852) 2508 1846Publication 22HIM-QR001F – September 2009Supersedes 22HIM-QR001E-EN-P – April 2005
Copyright © 2009 Rockwell Automation, Inc. All rights reserved. Printed in USA.
23
NOTE: New settings to HIM parameters are implemented immediately. Resetting the HIM is not required for new values to take effect.