塑料绝缘软线明敷设时的安全载流量标称截面单根单芯(A)二根单芯三根单芯(㎜2)25℃30℃35℃40℃25℃30℃35℃40℃25℃30℃35℃40℃RV0.154.543.543.53332.52.52RV0.276.565.55.554.5443.533RV0.3987.5776.565.554.543.5RVV0.411109.58.58.57.576.565.554.5RVB0.51312119.59.58.587.576.565.5RVS0.8161514131312119.5987.57RFB11917161515141211111098RFS1.5242221181917161514131211橡皮绝缘电线穿钢管敷设时的安全载流量(A)标称截面(㎜2)11.52.54610BX16BXF25(铜芯)3550709512015202837496886113140175215260300二根单芯环境温度25℃30℃35℃40℃管径(㎜)G三根单芯环境温度25℃30℃35℃40℃DG管径(㎜)G四根单芯环境温度25℃30℃35℃40℃DG管径(㎜)GDG1418263445638010513016320124328012172432425874971211511852242591115222938536889110138170205237151515202025253232405070702020202525323240405050──141825304056719311414318021925213162330405671931141431802192521215212837516686105133166203233111419263447607996121152185213151515202025323232505070702020202525323232405050──121723303953699011013717321024511152128364964841021281611962291014192533455977951181491812119131823304154718710813616619315202020202532404050707070202525252532405050────1503403172942687018538535933330480─31028926824570─35533130728080─28026124222180─32029927625380──橡皮绝缘电线穿硬塑料管时的安全载流量(A)标称截面(㎜2)11.52.54610BX16BXF25(铜芯)3550709512015018513172533435976100125160195240278320360二根单芯环境温度25℃30℃35℃40℃管径(㎜)三根单芯环境温度25℃30℃35℃40℃管径(㎜)四根单芯环境温度25℃30℃35℃40℃管径(㎜)1215233040557193116149182224259299336111421283751658610813816820724027631110131926344660799812615418921925328415151520202532324040505065658012162230385268901101401752152502903301114202835486384102130163201233271308101319253244587795121151185216250285912172330415371871101381701972292611515152020253232405050656565801114202634466080981231551952272653001013182431435674911151441822122472809121722293951698410613416819622925981115202636476377971221541792092371520212225323240405050658080100聚氯乙烯绝缘电线穿钢管敷设时的安全载流量(A)标称截面(㎜2)11.52.54610BV1625(铜芯)3550709512015018514192635476582107133165205250290330380二根单芯环境温度25℃30℃35℃40℃管径(㎜)G三根单芯环境温度25℃30℃35℃40℃DG管径(㎜)G四根单芯环境温度25℃30℃35℃40℃DG管径(㎜)GDG131724324360761001241541912332703083551218223040567092115142177216250285325111520273751648410513016219722926130015151515152002525323250505070701515151520252532405050505050─131724314157739511514618322526030034012152228385368881071361712102432803171114202635496382991261581942242592941013182432455775901151441772052372681515151515202532324050505070701515151520253232405050────111622283750658510513016520023026530010142026344660799812115418721524728091319243243567390112142173198229259812172229395167831021301581812092371515151520252532325050707070801515152025253240505050────聚氯乙烯绝缘电线穿硬塑料管时的安全载流量(A)标称截面(㎜2)11.52.546101612162431415672二根单芯环境温度25℃30℃35℃40℃管径(㎜)三根单芯环境温度25℃30℃35℃40℃管径(㎜)四根单芯环境温度25℃30℃35℃40℃管径(㎜)BX1114222838526710132026354862912182432445615151520202532111521283649651014192633456091318243142568121622283851151515202025321013192532445791217232941538111621273849710151825344515152020253232BXF2595(铜芯)351205015070185952301202701503051853558811214017221525228533182103129160198233263307759411814618121324128032404050506565808510513216720524027528979981231561912242572897390114144177207237268678310413016218921724532405050656565807593117148185215250280708610913817220123326164801011281601852162425973921171461721972214050636375757590BVV型和BLVV型熟料护套线规格、结构尺寸及参考载流量表标称截面(㎜2)11.52.545681011111177线芯结构绝缘根数直径层厚㎜1.131.371.762.242.52.731.21.33㎜0.60.60.60.60.80.80.80.8护套厚度最大外径BVV型参考载流量BLVV型参考载流㎜㎜(A)(A)单双三芯单芯双芯三芯单芯双芯三芯单芯双芯芯0.70.84.14.1×6.74.3×9.520161315124.6×0.70.84.44.4×7.2252116191610.30.70.84.84.8×7.85×11.534262226225.5×0.70.85.35.3×9.1453829352913.16.3×6.7×0.816.3514333393310.715.76.5×6.9×0.816.5564736433611.316.57.9×8.3×11.27.9705946544513.619.48.4×8.8×11.28.4857255665614.520.7流量表考载流量A)
三芯1012172326283543
因篇幅问题不能全部显示,请点此查看更多更全内容